Switchgear

MV primary switchgear, air or gas insulated.

Robustly engineered for a very long service life and excellent reliability, with competitive pricing and lead times.

Metal clad medium voltage switchgear from 3.6 to 40.5 kV for zone and bulk supply substations, industrial plants and renewable generation.

Withdrawable air insulated cubicles with vacuum circuit breakers, and gas insulated cubicles in a sealed stainless steel tank, rated up to 4,000 A and 40 kA.

Gas insulated medium voltage switchgear, four panels of different types in a row
Voltage class
3.6 to 40.5 kV
Rated current
630 to 4,000 A
SC breaking current
Up to 40 kA
Insulation
Air or SF6 gas

The range

MV primary switchgear is supplied as individually configured cubicles for incomers, feeders, bus sections and metering, matched to your network fault level, busbar rating and protection scheme.

Withdrawable, 3.6 to 12 kV

Handcart vacuum circuit breaker cubicles for 630 A to 4,000 A and fault levels from 20 to 40 kA, in 800 and 1,000 mm wide cubicles. Built for single busbar and sectionalised busbar substations.

Withdrawable, 24 kV

Cubicles rated 630 A to 2,500 A and 20 to 31.5 kA for 11, 22 and 24 kV networks, in 800 and 1,000 mm widths.

Withdrawable, 40.5 kV

Single busbar and sectionalised busbar switchboards for 33 kV networks, rated up to 2,000 A and 31.5 kA, with vacuum or SF6 circuit breakers.

Slim Cubicles for Restricted Switchrooms

Cubicles only 500 mm and 550 mm wide, rated 12 kV, 1,250 A and 31.5 kA, that can be installed against a wall with a single operating aisle at the front, reducing switchroom floor area.

Gas Insulated, 40.5 kV

Circuit breaker and load switch cubicles in a sealed stainless steel gas tank, 500 mm and 450 mm wide, for sites where space, pollution or maintenance access is a constraint.

Digital Monitoring

Optional online monitoring of temperature and arc light, with real time data, risk warning and remote access, for operators who want condition information from the switchboard.

Specifications

Typical ratings for the standard range. Final values are confirmed for each project.

Customised designs available. If your project needs ratings, features, design requirements or arrangements outside the standard range below, we design and manufacture to your requirements and application.

Technical dataMV primary switchgear
ParameterStandardOptional or on request
Rated voltage3.6 to 12 kV, 24 kV and 40.5 kV 
Rated frequency50 Hz 
Rated current
3.6 to 12 kV630 to 4,000 A 
24 kV630 to 2,500 A 
40.5 kV air insulated630 to 2,000 A 
40.5 kV gas insulated630 A 
Short circuit breaking current and short time withstand current (4 seconds)
3.6 to 12 kV20, 25 or 31.5 kA40 kA
24 kV20, 25 or 31.5 kA 
40.5 kV air insulated20, 25 or 31.5 kA 
40.5 kV gas insulated, circuit breaker31.5 kA 
40.5 kV gas insulated, load switch25 kA 
Peak withstand and making current50, 63 or 80 kA100 kA (up to 12 kV)
Internal arc classification (1 second)
3.6 to 12 kV40 kA 
24 kV31.5 kA 
40.5 kV gas insulated, circuit breaker31.5 kA 
40.5 kV gas insulated, load switch25 kA 
Circuit breakerWithdrawable vacuum circuit breakerSF6 circuit breaker (40.5 kV air insulated)
Degree of protection
Air insulatedIP4X enclosure, IP2X compartments 
Gas insulatedIP4X enclosure, IP67 gas tank 
Cubicle size, 3.6 to 12 kV
Width800 or 1,000 mm500 or 550 mm slim cubicle
Depth1,500 or 1,700 mm 
Height2,300 mm 
Cubicle size, 24 kV
Width1,000 mm 
Depth1,860 mm2,260 mm deep version
Height2,430 mm 
Cubicle size, 40.5 kV air insulated
Width1,400 mm 
Depth2,800 mm 
Height2,600 mm 
Cubicle size, 40.5 kV gas insulated
Width, circuit breaker500 mm 
Width, load switch450 mm 
Depth1,000 mm 
Height2,200 mm 
Gas insulated power frequency withstand voltage
Phase to phase and to earth95 kV 
Across open contacts118 kV 
Gas insulated lightning impulse withstand voltage
Phase to phase and to earth185 kV 
Across open contacts215 kV 
Gas insulated mechanical life
Circuit breakerAt least 10,000 operations 
Load switchAt least 5,000 operations 
Earthing switchAt least 3,000 operations 
Gas insulated SF6
Gauge pressure at 20°C0.04 MPa or less 
Annual leakage rate0.01% or less 

Design and performance

Air insulated cubicles keep every function in its own compartment, and gas insulated cubicles seal the live parts away from the environment altogether.

Metal Clad Compartments

Circuit breaker, busbar and cable compartments are separated, with IP4X enclosures and IP2X compartments. Cubicles for up to 12 kV have passed internal arc testing, and 24 kV cubicles are classified to 31.5 kA for 1 second.

Corrosion Resistant Construction

Cubicle bodies are folded from aluminium zinc coated steel on CNC machinery, giving strong resistance to corrosion and oxidation, high mechanical strength and low weight.

Slim and Compact Options

Cubicles 500 mm and 550 mm wide reduce switchroom footprint, by up to 60% in the slimmest case, and can be connected directly to high current cubicles for easy extension.

Sealed Gas Insulation

In the gas insulated range all primary live parts sit in a stainless steel tank filled with SF6, unaffected by dust, humidity, pollution and temperature variation. The circuit breaker uses a maintenance free vacuum interrupter, and the load switch uses a low pressure SF6 puffer arc extinguishing principle.

Integrated Isolation and Earthing

Gas insulated cubicles combine an isolating and earthing function with the vacuum circuit breaker, or use a three position load switch, for a compact footprint.

Condition Monitoring

Optional temperature and arc light monitoring, real time data display, risk warning and remote operation through cloud and mobile platforms.

Applications

Delstar supplies primary switchgear for:

01

Zone and bulk supply substations

Incomer, feeder and bus section switchboards for 11, 22 and 33 kV networks.

02

Industrial plants and mining

Reliable MV distribution for process loads and large motors, with internal arc protection for people and plant.

03

Power stations and generation

Station auxiliary supply and generator connection switchgear.

04

Wind farms and solar generation

Collector and connection switchboards, including gas insulated cubicles for onshore and offshore sites.

05

Urban and commercial substations

Compact and slim cubicles where switchroom space is limited.

Sourcing and quality assurance

Our primary switchgear is produced in a factory that holds ISO 9001, ISO 14001 and ISO 45001 certification. Sheet metal is CNC punched, laser processed and folded, and surfaces are cleaned, degreased and coated on an automated powder coating line for uniform thickness and strong corrosion protection. Type test reports are available for the range. Delstar delivers to site across New Zealand, Australia and the Pacific.

Lifecycle support

  • Specification and configuration: we help select the cubicle arrangement, breaker rating, protection and monitoring for your network.
  • Installation and commissioning: see Installation and commissioning.
  • Training and demonstration: hands on training or demonstrations at your workshop or facility, provided through our engineering services.
  • Spares and asset management: spares and ongoing support through our asset management service.

Talk to our team

Specify your primary switchgear requirement.

Tell us the voltage class, rating, fault level and installation environment, and any customised requirement. We will match the specification to the right configuration, or design and manufacture to suit.