Single Phase Meters
One single phase meter platform for prepaid, postpaid and smart metering. Run it as a prepaid meter with STS 6 token entry, as a postpaid meter, or as a smart meter with communications built in. Prepaid and postpaid meters can be supplied without communications and have a plug in module fitted at installation or added later, so meters already in service can join an AMI network without being replaced. Single element and two element versions are available. Four quadrant measurement, up to 8 tariffs, load profiles and event logs, with an optional load switch.
| Prepaid | STS6 compliant. Pay in advance, with credit loaded by token or remotely |
|---|---|
| Postpaid | Conventional billing, no communications. Communications can be added later |
| Smart | Prepaid or postpaid with communications built in |
| Reference voltage | 120 to 240 V |
|---|---|
| Current | 5 (80) A Optional: 5 (100) A |
| Accuracy | Class 1.0 kWh; class 2.0 kvarh |
| Frequency | 50 Hz, ±5% Optional: 50 or 60 Hz, ±2% |
| Measurement | Four quadrant, import and export active, reactive and apparent energy |
| Elements | Single element or two element |
| Operating voltage range | 70% to 130% of reference voltage |
| Impulse voltage withstand | Rated 6 kV impulse per IEC 62052-11 Withstands surges well above this requirement |
| Continuous overvoltage | Meets IEC 62052-11 Withstands sustained overvoltage well above this requirement |
| AC voltage withstand | 4 kV |
| Fast transient burst immunity | 4 kV |
| Tariffs | Up to 8 tariffs, 6 seasons, 100 special days |
| Load profile | Up to 32 channels; 30 minute interval and up to 90 days by default |
| Payment modes | Prepayment or postpayment; three level credit alarm; emergency credit, friendly time and friendly days |
| Token entry | Remote credit transfer Optional: 20 digit STS 6 tokens by keypad |
| Load switch | None Optional: Bi-stable relay, to 90 A |
| Communications | Plug in module, fitted at installation or retrofitted later Optional: Communications built in (smart version) |
| WAN communications | Plug in module Optional: G3-PLC, BPLC, Wi-SUN RF mesh, LoRaWAN, GPRS, 3G, 4G, NB-IoT, LTE-M |
| HAN communications | Optical port Optional: RS485 or M-Bus; built in RF or power line |
| Standards | IEC 62052-11; IEC 62053-21 and 62053-23; EN 50470-1 and 50470-3 (European MID); IEC 62055-31 for prepaid |
| Certification | SGS certified; type tested to IEC and European standards |
| Data protocol | DLMS/COSEM, with low level and high level security Optional: Security Suite 1 (three phase) |
| Firmware upgrade | Local interface and over the air |
| Event logging | Fraud, failure, power quality and security events |
| Protection | IP54; Class II insulation |
| Operating temperature | −25°C to +55°C Optional: −40°C to +70°C limit range |
| Humidity | Up to 95%, non-condensing |
| Design life | 15 years or more |